Applications —
Food & Beverage

Process
Requirement–
Twice a week a hot sauce manufacturer
receives a 10,000 gallon truckload of chili peppers suspended in
water.
They need a method to verify the
truck scale tickets as well as improve inventory records but truck
scales would be very expensive and most flowmeters would have
problems measuring the pepper slurry.
|
| |
Solution–
The Sparling Tigermag EP with
Optional Batcher |
| |
 |
 |
- Obstructionless
- no moving parts - no maintenance - minimal pressure drop
- ±0.5%
NIST certified accuracy
to verify truck scale tickets and improve inventory record
- Backlit
display easily read at
night
- Pulse
output to an additional
resettable totalizer allowed operators to reset individual truck
load totals without bothering the inventory count
- Meter
only requires 3 diameters of unobstructed pipe upstream and 1
diameter downstream making
it easy to find a place to install it
|
 |
 |
Sparling
Tigermags have been used by many breweries in applications such as:
• Boiler Feed Water
• Green Beer (Ruh to Storage)
• Water Usage to Finishing Cellars
• Finished Beer Blending
|
| Why Tigermags? |
|
|
With Mag-Command you
never have to open the enclosure to program your meter, protecting
sensitive electronics from environmental damage.
Software menus in plain English
lead the user easily through the programming process - no obscure
codes to learn!
|
|
|
Transmitter
electronic modules can be exchanged between units. Meter sensors
can be interchanged (as long as liner, electrode materials and
flow ranges are compatible). Reconfiguration is a snap with Mag-Command! |
|
|
Gallons, liters,
cuft, cubic meters or user defined - it's up to you! |
|
|
- 4-20mA output for rate -
- Pulse for your totalizer -
- Open collector to drive other
instrumentation
- Optional HART(R) Protocol
|
|
|
NEMA-4X withstands
washdown and weather. |
 |
Process
Requirement–
An orange juice producer was planning a highly visible expansion
of orange juice pulp feed at their facility. Their current
measurements were mechanical with visual observations. This was
slow and resulted in "off-spec" product. |
Solution–
Sparling
Tigermag
with Optional Hart Protocol
and FDA approved liners
Sparling delivered seven remote
mounted magmeters two (2) weeks ARO. By automating their process
the client saved over $500,000 a year by minimizing
"off-spec" product, improving accuracy and expanding
throughput.
|
|
|
|
Copyright
© 2002 by Cross Instrumentation
Specifications subject to change without notice - 10/01/02
NOTE:
The information provided
above has been compiled and published as a convenience to our
customers. All technical designs, advice, and recommendations,
including but not limited to, that appearing on this document are
rendered free of charge. As a result, Cross Instrumentation
disclaims any responsibility or liability to the buyer or user of
this information for any result obtained or damages incurred by
reason of the use or application of the design or other information
contained herein. |