WP/Dynamic - BMF Series
Originally
designed for measurement of brine solutions, the BMF series
is ideal for measuring caustics sodas to 20%, Saline water
to 10%, Glycol-water solutions to 30% & other Caustic
solutions with pH values up to 9
Description/Application:
 |
Available in sizes ranging from 2" (50mm) to 8"
(200mm) |
 |
Cold
Liquids to 122° F |
 |
Hot
Liquids to 266° F |
| |
|
 |
|
|
Accessories |
Electronics, Inline Strainers, Insulated Blankets |
 |
 |
REED Style - Low Frequency Pulsed Output;
2-wire low frequency volt-free contact closure
pulser;
RD-01 is designed for use in Cold applications only;
RD-02 is designed for use in both Hot & Cold
applications |
|
Performance Data - Reed Style Pulser |
|
 |
 |
OPTO Style - High Frequency Pulsed Output
The OPTO-01/02 is a 2-wire current switching
device for use in both Cold (OP-01) and Hot (OP-02)
water applications. This type of pulser is normally
used for conversion to analog signals; (4-20mA) or
as inputs to high definition batching units. |
|
Performance Data - OPTO Style Pulser |
|
 |
|
FM1-D/K -
Frequency to Current Converter |
The
FM-1D/K is a µP-controlled frequency converter with
display.
It converts input pulses to an analog current signal
proportional to
the momentary flowrate. Simply put... the FM-1D/K
converts the
Pulse input into a scaleable 4-20mA output. |
|
Incoming
Pulses are converted to: |
 |
Standard
signal current output (4-20mA) |
 |
Pulse
Totalization |
 |
Remote
LED Indication of Flow-Rate or Total
|
|
 |
CDL - Data
Logger
Portable Data Storage of Temperature, Pressure,
Level & Flow
|
 |
The CDL
Data Logger is a mobile system that records measured
values from reticulation networks independent of the
main power supply. Review and evaluation are
accomplished using a PC and Meinecke’s CDL-WIN
software. |
|
 |
| Inline
Strainers |
|
Protect your Flowmeter by installing an Inline
Basket Strainer upstream. Relatively inexpensive
when compared to the cost of the equipment they
protect, strainers remove unwanted particles from
the pipeline before they have a chance to cause any
damage to expensive flowmeters. |
|
|
|
 |
| Insulated
Covers |
|
Protect, insulate and maintain process temperatures
with these durable insulated covers. Custom
made covers are available for all types of
flowmeters, transmitters and other instrumentation
products. |
|
| |
For more
information on Meinecke Accessories
Call the Flow Specialists at CROSS INSTRUMENTATION |
|
|
Product Selector
Guide |
WP/Dynamic
/ WP-BMF
Cold/Hot
US Gallon & M3/Hr Registers
150lb ANSI RF Flanges |
Product
Selector
Stock
Items (Typical Quantities)
NOTE: Stock Meters are equipped with
US Gallon Registers & ANSI 150lb RF Flanged
Connections |
WP-HP
Cold
/
Hot
US Gallon & M3/HrRegisters
300lb ANSI RF Flanges |
|
Size
ŕ
â
Type
|
2"
(50mm) |
3"
(80mm) |
4"
(100mm) |
6"
(150mm) |
8"
(200mm) |
10"
(250mm) |
12"
(300mm) |
|
WPD-Cold |
828595
(10) |
828601
(8) |
828603
(8) |
828607
(4) |
828717
(2) |
828719
(1) |
828743
(1) |
|
WPD-Hot |
828596
(2) |
828602
(2) |
828604
(1) |
828608 |
828718 |
828720 |
828744 |
|
WPD BMF Cold |
828680 |
828982 |
828983 |
828985 |
828986 |
N/A |
N/A |
|
WPD BMF Hot |
828987 |
828989 |
828990 |
828992 |
828993 |
N/A |
N/A |
|
WP-HP Cold |
827444 |
827450 |
827456 |
827462 |
827468 |
828182 |
828188 |
|
WP-HP
Hot |
826364 |
827451 |
827457 |
827463 |
827469 |
828183 |
828189 |
|
|
Cross instrumentation |
|
Phone: (800)332-3418 |
Fax:
(770) 929-8278 |
Email:flowsolutions@crossco.com |
|
|
|
Literature
- Product
Brochures, Data Sheets Instruction Manuals
 |
|
Meinecke |
 |
|
Library |
|
 |
 |
 |
 |
 |
 |
| |
WP/D
Cold |
WP/D WP-QF
Hot |
WP/D BMF |
Pulsers |
FM-1D/K |
CDL Data
Logger |
|
CI
Product Brochure |
 |
 |
 |
 |
 |
 |
|
Factory Data Sheet |
 |
 |
|
WP/D |
WP-QF |
|
 |
 |
|
WP/D |
WP-QF |
|
 |
 |
 |
|
Reed |
OPTO |
|
 |
 |
|
Installation Manual |
 |
 |
 |
 |
 |
 |
|
|
|
|
|