Flanged Turbine Meters

Flowmeters Accessories Product Selector Library
History The Factory Production Factory Calibration

Dimensional Data - WP/Dynamic

The installation site should be chosen so that an unrestricted straight pipe of at least 3 Pipe Diameters is ensured.

The Pipe Diameter should not be reduced directly in front of or behind the meter.

All Regulation of the flow should be done behind the meter.

The meter must be installed in the pipe free of stress.

The location of the meter should be such that it is not possible for air pockets to develop in the meter I.e. the meter should not be at high points in the pipeline or operated under half full pipe conditions.

NOTE: Refer to Meinecke Water Meter Operating Instructions (Pamphlet Y128E) for complete operating instructions.

 

Meter
Size

2"
50mm

3"
80mm

4"
100mm

6"
150mm

8"
200mm

10"
250mm

12"
300mm

in.

mm

in.

mm

in.

mm

in.

mm

in.

mm

in.

mm

in.

mm

A

7 7/8

200

8 15/16

225

9 13/16

250

11 13/16

300

13 3/4

350

17 11/16

450

19 11/16

500

B

2 7/8

73

3 3/4

95

4 1/8

105

5 5/16

135

6 3/8

162

7 5/8

194

8 7/8

226

C

4 3/4

120

5 7/8

150

5 7/8

150

6 15/16

177

8 1/8

206

9 1/8

231

10 1/16

256

Weight

lbs

kg

lbs

kg

lbs

kg

lbs

kg

lbs

kg

lbs

kg

lbs

kg

Meter

16.98

7.70

29.98

13.60

39.68

18.00

78.26

35.50

111.33

50.50

159.39

72.30

218.92

99.30

Measuring Element

3.09

1.40

6.61

3.00

6.61

3.00

12.13

5.50

16.53

7.50

16.53

7.50

16.53

7.50

Body

13.89

6.30

23.37

10.60

33.07

15.00

66.14

30.00

94.80

43.00

140.65

63.80

202.38

91.80

 

Contact Information Resource Directory E-News Archives

Meinecke
Flanged Turbine Meters
Back Home Forward Up Email

Copyright © 2002 by Cross Instrumentation 
Specifications subject to change without notice - 10/01/02

 
NOTE: The information provided above  has been compiled and published as a convenience to our customers. All technical designs, advice, and recommendations, including but not limited to, that appearing on this document are rendered free of charge. As a result, Cross Instrumentation disclaims any responsibility or liability to the buyer or user of this information for any result obtained or damages incurred by reason of the use or application of the design or other information contained herein.