Back One Page  www.crossinstrumentation.com  Forward One Page  Mail - Meinecke Information Request

Flanged Turbine Meters 

Product Description

Pulsers: OD 01 - 02 - 03 - 04

Performance Data

High Frequency Pulsed Output
Type: OPTO-01/02/03/04

Description: The OPTO-01 is a 2 -wire current switching device for use with the WP/D Cold Water Meters. The   OPTO-02 is  for use with WP/D Hot Water Meters (can be used for cold water applications if needed).  This type of pulse is normally used for conversion to analog signals, (4-20mA) or inputs to high definition dosing/batching systems.

Principle: Light pulses are transmitted by an IR light diode onto a reflector wheel. The reflections are picked up by two detectors in the sensor head and processed electronically.  The micro-electronics are located in the capsule of the cable

Sensor Principle

IR-reflex light barrier acc. To DIN 19234, plug type

Specification

Supply voltage 8.2 Vdc
Current with reflection < 1.2 mA
Current without reflection > 2.1 mA
Forward/reverse identification integrated by an additional current barrier at 1.5mA

Pulse Duration

Depending on flow in the meter
At meter stop continuous pulse possible

Protection

IP 65 (DIN 40050)

Temperature Range

OD 01/03: ambient temperature < 70°C

OD 02/04: medium temperature < 50°C

Connection Cable

Length: 3M (10 feet)

 Pulse Values

Meter Size

2" to 4"

Dial Face: 100 USG

6" to 8"

Dial Face: 1,000 USG

10" to 12 "

Dial Face: 10,000 USG

Cold Water Meters

OD 01

1 Pulse per 0.1 USG

1 Pulse per 1.0 USG

1 Pulse per 100.0 USG

OD 03

1 Pulse per 1.0 USG

1 Pulse per 10.0 USG

1 Pulse per 1000.0 USG

Hot Water Meters

OD 02

1 Pulse per 0.1 USG

1 Pulse per 1.0 USG

1 Pulse per 100.0 USG

OD 04

1 Pulse per 1.0 USG

1 Pulse per 10.0 USG

1 Pulse per 1000.0 USG

 

Additional information on
this product(s) is available via 
the email link below:

 

Copyright © 2002 by Cross Instrumentation 
Specifications subject to change without notice - 10/01/02

 
NOTE: The information provided above  has been compiled and published as a convenience to our customers. All technical designs, advice, and recommendations, including but not limited to, that appearing on this document are rendered free of charge. As a result, Cross Instrumentation disclaims any responsibility or liability to the buyer or user of this information for any result obtained or damages incurred by reason of the use or application of the design or other information contained herein.