Flanged Turbine Meters 

 

Distributed throughout the America's by the Flow Specialists @ CROSS INSTRUMENTATION   
Phone (770) 929-8441 ~  Fax (770) 929-8278

Flow Meters -  For Hot and Cold Water Service - WP/Dynamic, WP/Dynamic BMF                 Top

WP/Dynamic - Cold Water Meter

WP/Dynamic

Bulk liquid meter for measurement of high, 
relatively constant flows of both cold and hot wate
r

 
Description / Application
    Bulk liquid meter for cold and hot  water service
    With its high degree of accuracy and the versatility of its accessories, 
         it can be utilized for automatic batching, local or remote totalization or 
         remote rate of flow indication
    Available in sizes ranging from 2" (50mm) to 12" (300mm)
    Process Connection: ANSI 150lb (std) & 300lb (opt)  RF  Flange
    Cold Water to 122° F - Hot Water to 266° F
    Measurement accuracy of +/- 2% on flows 
         ranging from 2.0 GPM to 8,800 GPM
    Replaceable measuring element can be removed for maintenance
         and/or replacement without removing the meter housing from the line
 

WP/Dynamic - Hot Water Propeller Meter

WP/Dynamic - BMF Series for Brine & Light Caustic Solutions

 

WP/Dynamic BMF
Originally designed for measurement of brine solutions, the BMF series 
is ideal for measuring caustics sodas to 20%, Saline water to 10%, 
Glycol-water solutions to 30% & other Caustic solutions with pH values 
up to 9 
    Available in sizes ranging from 2" (50mm) to 8" (200mm)
    Cold Liquids to 122° F
    Hot Liquids to 266° F

Accessories - Electronics, In-Line Strainers                                                                                 Top

 

 


Opto Style Pulser

Pulsers 

    REED Style - Low Frequency Pulsed Output
The REED-01/02 is a 2-wire low frequency volt -free contact closure pulser.  
 RD-01 is used in Cold Applications. RD-02 is used with Hot Water Meters.

           Performance Data - REED         

    OPTO Style - High Frequency Pulsed Output
The OPTO-01/02 is a 2-wire current switching device for use in both Cold (OP-01) and Hot (OP-02) water applications. This type of pulse is normally used for conversion to analog signals; (4-20mA) or as inputs to high definition batching units.
          
Performance Data - OPTO     

FM-1D/K - Frequency to Current Converter

FM-1D/K - Frequency to Current Converter

The FM-1D/K is a µP-controlled frequency converter with display.
It converts input pulses to an analog current signal proportional to
the momentary flowrate.  Simply put... the FM-1D/K converts the 
Pulse input into a scaleable 4-20mA output.

Incoming Pulses are converted to:
     Standard signal current output (4-20mA)
     Pulse Totalization
     LED Indication of Flow-Rate or Total

CDL - Data Logger

CDL - Data Logger 
Portable Data Storage of
Temperature, Pressure, Level & Flow

The CDL Data Logger is a mobile system that records measured values from reticulation networks independent of the main power supply. Review and evaluation are accomplished using a PC and Meinecke’s CDL-WIN software.

In-Line Strainers 

Protect your MEINECKE Propeller Meter by installing an In-Line Basket Strainer upstream.  Relatively inexpensive when compared to the cost of the equipment they protect, strainers remove unwanted particles from the pipeline before they have a chance to cause any damage.  

          For more information on In-Line Strainers...
    
Call the Flow Specialists at Cross Instrumentation

 

Product Selection Guide - Model Numbers, Stock Meters                                                     Top

WP-Dynamic Registers
Cold: US Gallon & M3/Hr
Hot: M3/Hr Only 
(For USG - Use: WP-QF)

Product Selector
  Stock Item  (Qty-Typical) 
Note: All Stock Meters are equipped with US Gallon 
Registers and ANSI 150 RF Process Connections
 

WP-QF Registers
Cold/Hot WaterMeters:
US Gallon / M3/Hr

    Meter Size Meter Type

2”
(50mm)

3”
(80mm)

4”
(100mm)

6”
(150mm)

8”
(200mm)

10”
(250mm)

12”
(300mm)

WP/D Cold

82 85 95 
(10)

82 86 01
 (8)

82 86 03
(8)

82 86 07
(4)

82 87 17
(2)

82 87 19
(1)

82 87 43
(1)

WP/D Hot

82 85 96

82 86 02

82 86 04

82 86 08

82 87 18

82 87 20

82 87 44

BMF-Cold

82 86 80

82 89 82

82 89 83

82 89 85

82 89 86

N/A

N/A

BMF-Hot

82 89 87

82 89 89

82 89 90

82 89 92

82 89 93

N/A

N/A

WP-QF Cold

82 62 43

82 63 92

82 62 55

82 64 85

82 65 09

82 65 69

82 65 93

WP-QF Hot

82 62 46
(3)

82 63 93
(2)

82 62 56
(2)

82 64 86

82 65 10

82 65 70

82 65 94

Literature - Product Brochures, Data Sheets, Installation Manuals                                    Top     

 Meinecke
Library
 

WP/D Cold

WP/Dynamic - Hot Water Propeller Meter

WP/D - QF Hot

WP/Dynamic - BMF Series for Brine & Light Caustic Solutions

WP/D BMF

Opto Style Pulser

Pulsers

FM-1D/K - Frequency to Current Converter

FM-1D/K

CDL - Data Logger

CDL Data Logger

CI-Product Brochure

Factory Data 
Sheets

WP/D WP-QF
WP/D   WP-QF

  
Reed    Opto

Installation Manual

Join the Cross Instrumentation/Meinecke mailing list
Email:
   

Additional information on
this product(s) is available via 
the email link below:

 

Copyright © 2002 by Cross Instrumentation 
Specifications subject to change without notice - 10/01/02

 
NOTE: The information provided above  has been compiled and published as a convenience to our customers. All technical designs, advice, and recommendations, including but not limited to, that appearing on this document are rendered free of charge. As a result, Cross Instrumentation disclaims any responsibility or liability to the buyer or user of this information for any result obtained or damages incurred by reason of the use or application of the design or other information contained herein.