|
|
|
Digiflow®FLS |
Paddle Wheel Flow Meters & Instrumentation |
|
Type 100 Flow Sensor | |||
| The Type 100 Flow Sensor is the core item in the FLS Paddle Wheel line of sensors. Most of it's specifications are common to the Digiflow FLS product line. | ||||
|
|
Product Data Sheets | Additional Information | ||
|
|
||||
|
|
Battery Powered Flow Meters |
|||
| The Type 215 Point-of-Use Flow Indicator/Totalizer uses a standard 3.6V Lithium battery. A coil effect pulse output flow sensor is employed. In a NEMA 4X is an LCD digital display which shows flow rate (4-digits) or total flow (6-digits) in any volumetric unit. Calibration is easily performed in the field using the keypad. Installation fittings are required. Another battery powered flow meter is the Type 100BP / 400BP which includes a surface mount indicator/totalizer and a separate flow sensor. The indicator may be installed up to 10 meters away in a convenient reading location. | ||||
|
||||
|
|
Data Sheets | |||
|
|
||||
![]() |
Flow Transmitters | |||
| The Type 2110 is a 2-wire flow transmitter with 4-20mA output. A hall effect pulse output sensor is employed. In a NEMA 4X is an LCD digital display which shows flow rate (4-digits) or total flow (6-digits) in any volumetric unit. Calibration is easily performed in the field using the keypad. Installation fittings are required. 3-Wire units are available. | ||||
|
||||
|
|
Data Sheets | |||
|
|
||||
![]() |
No-Flow Switches | |||
| The Type 105 No-Flow Switch opens an electrical circuit when flow velocity decreases to the preset trip point. Typical applications are to protect a pump from running dry or pumping against a closed valve in the main pipe. A red/green bicolor LED indicates status locally: Red = No Flow, Green = Flow | ||||
|
||||
|
|
Data Sheets | |||
|
|
||||
![]() |
Ultra Low Flow - Flowmeters (3 Types Available) | |||
| Type ULF Flow Sensor - Produces a Hall Effect pulse output that is proportional to the flowrate. Output is normally fed to a panel mount instrument. Supply voltage is between 12 & 24Vdc. | ||||
|
Type ULF-FT Battery
Powered Flow Indicator/Totalizer - Reed Switch pulse output sensor is combined with flowrate/total flow LCD display (same as Type 215 above). |
||||
| Type ULF-XFT 2-Wire Flow Transmitter - Reed switch output sensor is combined with local flow rate/total LCD display. Output signal is 4-20mA proportional to the flowrate. | ||||
|
||||
|
|
Data Sheets | |||
|
|
||||
![]() |
Electromagnetic Flow Transmitters | |||
| The Type 3110 is an insertion type transmitter. Output is a 4-20mA analog signal proportional to the flowrate. Compared to the paddle wheel type, these units are better suited to handle slurries and high viscosity fluids. They are not affected by ferrous particles which will foul the magnetic rotors of the paddlewheel type meters. In addition, they are less costly than full port magmeters and easier to maintain. | ||||
|
||||
|
|
Data Sheets | |||
|
|
||||
|
|
|||
|
Quick Links: |
|||
| Digiflow
FLS Installation Instructions |
Digiflow
FLS Assembly Instructions |
||
| Misc. Flow Products from Cross Instrumentation | Meinecke Turbine Meters |
Cross Instrumentation |
|
|
|
|||